KASTAR

How do you specify MS973 on a sheet-metal joint?

This case is two uses on the MS973 sheet: connection joints in sheet-metal fabrication, and elastic bonding where the assembly vibrates. It does not name a customer.

Figures that belong to this grade

ItemOn the MS973 sheet
Named usesSheet-metal connection joints. Elastic bonding in constructions that vibrate.
Elongation at breakat least 200%
Shore A40–50
Tensile strengthat least 1.8 MPa
PaintWater-based paint after cure. Test the coating on a cured sample first.
Metal prepDegrease aluminium and stainless steel with alcohol or MEK. Lightly abrade other metals, then degrease them.

Handbook code 866 is an industrial-assembly commercial code. It stays separate until a data sheet maps it to MS973. The 20 kg and 200 kg lines in the handbook are packing times. They do not carry this strength table. A standard 600 ml sausage is 10–14 days. A 20 kg pail is 14–21 days. A 200 kg drum is 21–30 days, and the handbook asks for about 30 days of notice. Minimum order is 1 tonne, except the 200 kg drum. The price is on the proforma.

The joint stays out of a totally confined space. Apply from +5°C to +35°C.

中文

这个案例是数据表上的两处用途:金属板连接缝,以及有振动结构的弹性粘接。不点名客户。

KASTAR MS973 for construction joints

Use MS973 when the joint needs a one-component, moisture-curing sealant and water-based paint after cure. Do not use it in a closed void, below +5°C, or on polyethylene, PTFE or untested natural stone. The figures on that page are MS973 only.