Where should MS973 not be used?
Do not use KASTAR MS973 in a fully closed space, below +5°C or above +35°C, or on polyethylene, PTFE or natural stone until a compatibility test or a stain test on that substrate passes. The figures on the MS973 table stay with the universal grade.
A fully closed space
Moisture curing stops when the air holds no moisture. The sheet keeps the sealant out of a totally confined space.
Outside +5°C to +35°C
Apply between +5°C and +35°C. Below +5°C, wait. Above +5°C in winter, curing is slower. The PDF prints −50°C to 120°C under the heading “Construction work time”. That heading is not a service-temperature claim.
Polyethylene, PTFE and natural stone
Polyethylene and PTFE need a compatibility test first. On marble, granite or other natural stone, run a stain test on an off-cut before the job. The sheet asks for a compatibility test when the substrate is not confirmed.
Grades that do not inherit this table
MS973-KB is the kitchen and bath grade named for mould resistance. MS973-UW is the grade named for underwater curing. KASTAR 777, 978 and 866 stay separate commercial codes until a data sheet maps them to MS973.
Other buyer questions
Where is MS polymer sealant used? What temperature can MS973 be applied in? How long does a 600 ml MS sausage cover? Which substrates does MS973 bond to? Does MS sealant stain natural stone? Which grade is for kitchens and bathrooms? Is there an underwater-curing MS grade? What certificates are needed to import MS sealant into the EU? What document does a Serbia project ask for if it follows EN 15651? Is Kastar MS sealant a dangerous good for air freight? How do you apply MS polymer sealant?